© 2000 Scenix Semiconductor, Inc. All rights reserved.
75
SX Users Manual Rev. 3.1
www.scenix.com
Chapter 3 Instruction Set
program to continue with the instruction immediately following the call
instruction.
The addxy routine must start in the lower half of a 512-word page of the program
memory. This is because bit 8 of the subroutine address must be 0. The PA2:PA0
bits of the STATUS register must contain the three high-order bits of the subroutine
address prior to the call instruction. This is the purpose of the page instruction.