ON 20080405@11:44:07 AM at page:
http://www.sxlist.com/techref/scenix/rtcc.htm#39543.4889467593
James Newton[JMN-EFP-786] See also:
http://forums.parallax.com/forums/default.aspx?f=7&m=249607
When you modify RTCC the next several instructions don't increment RTCC. In effect, the instruction that modifies RTCC takes several RTCC counts
- If the prescaler is 1:8 or higher, the instruction that modifes RTCC is one count.
- If the prescaler is 1:2 or 1:4, the instruction that modifes RTCC is five counts. The next five instructions do not increment RTCC.
- If the prescaler is 1:1, the instruction that modifies RTCC is three counts. The next 3 instructions do not increment RTCC.
ON 20080405@4:29:27 PM at page:
http://www.sxlist.com/techref/scenix/rtcc.htm#38190.5464351852
James Newton[JMN-EFP-786] removed post 38190.5464351852
|Delete 'fr
'