SX Embedded Controller Instruction

OR fr1,fr2

Description: OR fr2 into fr1
Operation: fr1 |= W = fr2
Flags affected: Z
Registers affected: W fr1
Sources referenced: fr2
Cycles: 2
Opcode:
Actually compiles to: mov W, fr2; or  fr1, W
Microchip PIC syntax: MOVF fr2,0; IORWF fr1,1
Notes: