SX
Embedded Controller
Instruction
CLRB bit
Description:
Clear
bit
Operation:
fr,bit = !( 1 <<
bit
) &
fr
Flags affected:
none
Registers affected:
fr
bit
Sources referenced:
fr
Cycles:
1
Opcode:
Details:
SX Users Manual
page
# 81
Microchip PIC
syntax:
BCF bit
Notes: