IP2022 Data Sheet
www.ubicom.com
93
7.1.12 SxRCFG Register
SERDES RX shift count, USB sync detect and data
polarity configuration.
7.1.13 SxRCNT Register
SERDES RX activity configuration.
7
6
5
4
0
MASSEL SYNCDETEN RPOREV
RXSCNT4:0
Name
Description
MASSEL
10Base-T mode:
0 = Normal polarity detected
1 = Reverse polarity detected
GPSI or SPI mode:
0 = Slave mode
1 = Master mode
SYNCDETEN Synchronization byte detection enable
(USB mode only)
0 = Synchronization byte detec-
tion enabled
1 = Synchronization byte detec-
tion disabled
RPOREV
Receive data polarity reversal select
0 = Data polarity uninverted
1 = Data polarity inverted
RXSCNT4:0
Receive shift count, specifies number
of bits to receive
7
6
5
4
0
BITORDER RxCRSED RxCRS
RXACNT4:0
Name
Description
BITORDER
Bit order for transmit and receive
0 = LSB first
1 = MSB first
RxCRSED
Carrier sense interrupt control
10 = Interrupt on carrier detection
11 = Interrupt on loss of carrier
RxCRS
Carrier Sense Status: Current state
of carrier
RXACNT4:0
Receive shift count, actual number
of bits received (read-only). Excep-
tions occur during the last transfer:
RXACNT = 0 if bit count is
less than 8
RXACNT = 8 if bit count is
greater than or equal to 8, but
less than 16
RXACNT = 16 if bit count is
greater than or equal to 16
and the RXSCNT4:0 field in
the SxRCFG register is 16