PeripheralsIP2022 Users Manual
280
www.ubicom.com
4.6.5
SxRBUFH/SxRBUFL Register
16-bit register pair for unloading received data. The RXBF bit in
the SxINTF register indicates when new data has been loaded into
this register. If the corresponding bit in the SxINTE register is set,
an interrupt is generated.
4.6.6
SxRCFG Register
7
6
5
4
0
MASSEL SYNCDETEN RPOREV
RXSCNT4:0
Name
Description
MASSEL
10Base-T mode:
0 = Normal polarity detected
1 = Reverse polarity detected
GPSI or SPI mode:
0 = Slave mode
1 = Master mode
SYNCDETEN
Synchronization byte detection enable (USB mode only)
0 = Synchronization byte detection enabled
1 = Synchronization byte detection disabled
RPOREV
Receive data polarity reversal select
0 = Data polarity uninverted
1 = Data polarity inverted
RXSCNT4:0
Receive shift count, specifies number of bits to receive