PeripheralsIP2022 Users Manual
260
www.ubicom.com
OFIF
Timer overflow interrupt flag
0 = No timer overflow has occurred since this bit was
last cleared
1 = Timer overflow has occurred
CAP2IF
PWM mode: Compare 2 interrupt flag (i.e. timer value
matched TxCMP2 value)
CMP2IF
Capture/Compare mode: Capture 2 flag (i.e. TxCPI2 input trig-
gered)
0 = No capture/compare 2 event has occurred since
this bit was last cleared
1 = Capture/compare 2 event has occurred
CAP1IF
Capture 1 interrupt flag
0 = No capture 1 event has occurred since this bit was
last cleared
1 = Capture 1 event has occurred
CMP1IF
Compare 1 interrupt flag
0 = No compare 1 event has occurred since this bit was last
cleared
1 = Compare 1 event has occurred
MODE
Timer mode select
0 = PWM/timer mode
1 = Capture/compare mode
OEN
TxOUT enable bit
0 = TxOUT disabled. Port pin available for general-purpose
I/O.
1 = TxOUT enabled. Port pin must be configured for output
in corresponding RxDIR register bit.
Name
Description