Peripherals—IP2022 User’s Manual 260 www.ubicom.com OFIF Timer overflow interrupt flag 0 =   No timer overflow has occurred since this bit was           last cleared
1 =   Timer overflow has occurred
CAP2IF PWM mode: Compare 2 interrupt flag (i.e. timer value
matched TxCMP2 value)
CMP2IF Capture/Compare mode: Capture 2 flag (i.e. TxCPI2 input trig-
gered)
0 =   No capture/compare 2 event has occurred since           this bit was last cleared
1 =   Capture/compare 2 event has occurred
CAP1IF Capture 1 interrupt flag 0 =   No capture 1 event has occurred since this bit was           last cleared
1 =   Capture 1 event has occurred
CMP1IF Compare 1 interrupt flag 0 =    No compare 1 event has occurred since this bit was last           cleared
1 =    Compare 1 event has occurred
MODE Timer mode select 0 =    PWM/timer mode
1 =    Capture/compare mode
OEN TxOUT enable bit 0 =    TxOUT disabled. Port pin available for general-purpose           I/O.
1 =    TxOUT enabled. Port pin must be configured for output
in corresponding RxDIR register bit. Name Description