IP2022 Users ManualInstruction Set Architecture
www.ubicom.com
171
LOADL addr16
Load Low Data Address into DPL
Operation:
DPL = addr16(7:0)
Bits affected:
None
Opcode:
0111 0001 kkkk kkkk
Description:
This instruction loads the low 8 bits of a data
address into DPH. A skip over a loadl
instruction results in an extended skip (following
instruction also skipped).
From assembly language, a 16-bit address is
specified. The assembler takes the low 8 bits of
the address and encodes it in the instruction. The
high 8 bits are ignored.
Cycles:
1