On Tue, 27 Nov 2018 at 19:29, Neil wrote: > > I'm using an MCP73833-AMI for charging a 1-cell Lipo in a project. This > specific charger is looking for a charge voltage of 4.2V, but the > voltage never gets to over about 4.09V to 4.13V (tested over several > batteries). > > Datasheet: http://ww1.microchip.com/downloads/en/DeviceDoc/22005b.pdf uChip evaluation kit manual: http://ww1.microchip.com/downloads/en/DeviceDoc/51626a.pdf uChip Reference Design: http://ww1.microchip.com/downloads/en/DeviceDoc/51746a.pdf What thermistor (or what else) is on THERM pin? [data sheet / spec] (Lack of thermistor MAY alter voltage substantially). What value of Rprog? What charge current. What cell used (datasheet/type/...?) What package? Is exposed thermal pad connected to Vss? ____________________ Related uChip Portable Power Conversion Design Guide http://ww1.microchip.com/downloads/en/DeviceDoc/30009610F.pdf Cousin - 73831/2 http://ww1.microchip.com/downloads/en/DeviceDoc/20001984g.pdf Russell --=20 http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .