On Mon, 19 Nov 2018 at 16:26, James Cameron wrote: https://www.vishay.com/docs/83708/appnote50.pdf was the best for me, and yes, it is very comprehensive, giving bandwidth expected for each design. For interest: Bottom of last page: The zero biased photovoltaic amplifier offers a 50 kHz to 60 kHz usable bandwidth. When the detector is reverse biased to -15 V, the typical isolation amplifier response increases to 100 kHz to 150 kHz. The phase and frequency response for the IL300 is presented in Fig. 41. When maximum system bandwidth is desired, the reverse biased photoconductive amplifier configuration should be considered. Russell McMahon --=20 http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .