Interested if anyone has suggestions for building a contact fault locator circuit that would provide audible feedback as RF cables and connectors are wiggled and tapped. These cables terminate in Combiners and Transformers with a DC input impedance of around 0.4 ohms and between 50 - 500 ohms impedance for their usable frequency range . A multi-meter is useful for finding faults but has some drawbacks. It is slow to update and a little difficult to use in the field with sun, flies, rain, dust etc. Not really sure where to start. Perhaps injecting a sine wave of a given frequency which could be distorted as the faulty connectors are knocked. Any suggestions are warmly welcome. See below if keen for additional info. Cheers Justin As a Telstra tech we used a contact fault locator QD750017 (some are selling on Ebay at present) to test any coax cables that we manufactured. These coax cables carried up to 140Mb/s so it was important that we made quality connectors. To test, both ends were connected to the tester and then the cables were tapped with a piece of nylon as part of the knock test. The tester produced audible feedback and were excellent at detecting connectors that were not 100%. I currently help maintain a network that utilizes thousands of RF connectors. We have various methods to determine faulty connectors and components including System self diags (Slow and fails to pin point failure) Spectrum Analyser with tracking generator (Cumbersome but effective) Multimeter (Very effective but with slow visual feedback can miss faults) Recently while on repair duties I recalled the contact fault locators and am now curious how to build such a circuit. --=20 http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .