Should have mentioned that the JPG plots the error over the range of samples. On 20 October 2015 at 10:15, Justin Richards wrote: > I decided to measure and plot the error of the ESP8266 internal ADC. > > Thought I would share the results. > > PSU HP E3631A and Fluke 87 to set the voltage between 0 and 1.020 Volts. > > V Actual,V ADC > 0.01,0.001 > 0.02,0.008 > 0.03,0.017 > 0.04,0.028 > 0.05,0.038 > 0.06,0.05 > 0.07,0.06 > 0.08,0.07 > 0.09,0.08 > 0.1,0.09 > 0.11,0.102 > 0.12,0.113 > 0.13,0.124 > 0.14,0.136 > 0.15,0.149 > 0.16,0.158 > 0.17,0.168 > 0.18,0.18 > 0.19,0.189 > 0.2,0.2 > 0.21,0.209 > 0.22,0.221 > 0.23,0.232 > 0.24,0.242 > 0.25,0.253 > 0.26,0.266 > 0.27,0.275 > 0.28,0.285 > 0.29,0.297 > 0.3,0.306 > 0.31,0.316 > 0.32,0.326 > 0.33,0.338 > 0.34,0.35 > 0.35,0.356 > 0.36,0.367 > 0.37,0.38 > 0.38,0.394 > 0.39,0.404 > 0.4,0.412 > 0.41,0.425 > 0.42,0.438 > 0.43,0.447 > 0.44,0.458 > 0.45,0.466 > 0.46,0.477 > 0.47,0.488 > 0.48,0.496 > 0.49,0.508 > 0.5,0.518 > 0.51,0.53 > 0.52,0.54 > 0.53,0.552 > 0.54,0.562 > 0.55,0.573 > 0.56,0.582 > 0.57,0.593 > 0.58,0.603 > 0.59,0.613 > 0.6,0.625 > 0.61,0.635 > 0.62,0.649 > 0.63,0.66 > 0.64,0.669 > 0.65,0.678 > 0.66,0.693 > 0.67,0.701 > 0.68,0.711 > 0.69,0.722 > 0.7,0.731 > 0.71,0.744 > 0.72,0.753 > 0.73,0.763 > 0.74,0.776 > 0.75,0.785 > 0.76,0.795 > 0.77,0.81 > 0.78,0.816 > 0.79,0.829 > 0.8,0.835 > 0.81,0.847 > 0.82,0.857 > 0.83,0.868 > 0.84,0.878 > 0.85,0.891 > 0.86,0.901 > 0.87,0.914 > 0.88,0.925 > 0.89,0.936 > 0.9,0.945 > 0.91,0.957 > 0.92,0.965 > 0.93,0.977 > 0.94,0.986 > 0.95,0.998 > 0.96,1.006 > 0.97,1.018 > 0.98,1.024 > 0.99,1.024 > 1,1.024 > 1.01,1.024 > 1.02,1.024 > > --=20 http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .