On 14/05/15 04:44, Sean Breheny wrote: > I took out the fiberglass bodied elements and put them in a test circuit > which ran 10 Amps through them, one at a time. BOTH blew after about 10 > seconds. Since there is no way that a 30 Amp fuse could have a series > element which opened at only 10 Amps, this further confirmed my suspicion > that the fuse was mis-marked and probably this happened at the factory. > =20 My guess would be that they make and label the casings before assembling=20 the innards and that a casing ended up in the wrong bin between=20 manufacture of the casing and assembly of the complete fuse. --=20 http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .