Joe, Very true and I was going to add the ability to change the counting=20 time after I got the basic system up and working. In fact if we want to=20 we could do a very simple case of hold the count gate open for 1 second.=20 Display the value for 15 seconds. Reset the display with the 20-30ns=20 pulse. In fact I would use at least 30ns as 20ns is the minimum=20 specified time for the reset pulse. Open the counting gate again for 1=20 second and repeat forever. No ADC, pot or the code to read and process=20 the reading. Thanks, rich! On 7/18/2014 5:10 AM, IVP wrote: >>> Less than 1 percent would be worst case. If 1ppm could be >>> achieved that would be great but I don't know if that is possible. >>> I'm not going to use it for calibration work. >> But what is your crystal accuracy? > The meaningfulness of the result rather depends on what signal > frequency is being measured. For example, if it's only a few kHz > then the portion of a wave left off the count when the 1s is up > could be more significant than the ppm error of the PIC crystal > > Joe > > Nice to see some PIC on the list --=20 http://www.piclist.com/techref/piclist PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .