Thanks, that's an excellent approach, which will make things much simpler. On Wed, Jan 23, 2013 at 1:41 AM, Harold Hallikainen wrote: > These are my favorite 60Hz current sensing transformers: > > http://www.toroid.com/standard_transformers/current_sensing_transformers/= current_sensing.htm > > One trick is to run the secondary of the transformer through a diode > bridge, then the shunt resistor. Putting the diodes before the resistor > gets rid of diode drops since the transformer secondary is a current > source (until the voltage is high enough to saturate the core). > > Harold > > > -- > FCC Rules Updated Daily at http://www.hallikainen.com - Advertising > opportunities available! > Not sent from an iPhone. > -- > http://www.piclist.com PIC/SX FAQ & list archive > View/change your membership options at > http://mailman.mit.edu/mailman/listinfo/piclist --=20 KPL --=20 http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .