At 07:31 AM 8/23/2012, you wrote: >Yes, usually treadmill DC motors are used for lathes, but those are >unavailable here, and expensive to ship from places they are >available:) >Technically wound-stator motor with DC connected across it should be >equivalent to permanent-magnet motor. >But I'm not quite sure if it's that simple. Yes, it is just that simple. Many commercial motor controllers have a relatively low-current output to drive the field coils. Best regards, Spehro Pefhany --"it's the network..." "The Journey is the rewar= d" speff@interlog.com Info for manufacturers: http://www.trexon.co= m Embedded software/hardware/analog Info for designers: http://www.speff.co= m --=20 http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .