xavierpereira wrote: > http://dl.dropbox.com/u/20793649/Transformercoupled.JPG Transformer Coupl= ed > gate Drive=20 > http://dl.dropbox.com/u/20793649/Capacitvely%20Coupled%20Mosfet.JPG > Capacitively Coupled Gate Drive=20 > > > Can Some help me to know the difference between a Capacitively Coupled Ga= te > Drive and Transformer cuoupled Gate Drive ? > > I have to use the Transformer Coupled Gate Drive for My project=20 > But I cannot find one here in Bangkok > > can I replace it with Capacitively Coupled Gate Drive and what would be = the > effect ? > > http://dl.dropbox.com/u/20793649/Gate%20Driver.JPG My Gate Driver Circuit= =20 > =20 A 1:1 transformer can work. A small common mode filter can be used as a=20 1:1 gate drive transformer. if you need galvanic isolation, then capacitor coupling is no use. --=20 http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .