On Tue, 07 Jun 2011 13:23 +1200, "IVP" wrote: > It's a Metropolitan Vickers BC 2408. Fairly typical appliance- > type single-phase motor, 230V 1/4hp 1425rpm, with reduction > gearing and end-plate to drive the minute hand, which isn't that > minute BTW >=20 > I suspect that the problem is overheating. The motor runs but > after perhaps 20 seconds from cold it turns off. When it restarts > some seconds later the time until the next stop becomes > progressively shorter. The motor does seem to be hotter than > you'd expect after only a short run time.=20 Hi Joe, My first thought was it might be a synchronous motor as it's used in a time= piece=20 (deos it say 1500RPM on the faceplate instead of the usual 1425-1475?), in = which=20 case it might be cap run instead of cap start, without a centrifugal starti= ng switch.=20 Faulty cap may cause it to run hotter than normal and trip the automatic ov= erload=20 protection device/circuit? --=20 Brent Brown, Electronic Design Solutions 16 English Street, St Andrews, Hamilton 3200, New Zealand Ph: +64 7 849 0069 Fax: +64 7 849 0071 Cell: +64 27 433 4069 eMail: brent.brown@clear.net.nz --=20 http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .