At 01:42 PM 21/04/2011, you wrote: >Most the relays I've found do not include an inductive load spec > >24VDC coil >20A contacts, inductive >277VAC switched voltage >SPST-NO > >Ive found several that spec the contacts resistive, but not inductive. >I know that inductive is hard on the contacts, for arcing, so I am=20 >surprised I havent seen it on the data sheets What manner of inductive load? It's not unusual to have ratings for pf < 1.0, for motor loads, and/or for ballasts, all of which are inductive loads. Something that's almost purely inductive (say a big solenoid with no suppression) is an unusual type of load and will not be kind to the contacts. >Best regards, Spehro Pefhany --"it's the network..." "The Journey is the rewar= d" speff@interlog.com Info for manufacturers: http://www.trexon.co= m Embedded software/hardware/analog Info for designers: http://www.speff.co= m --=20 http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .