Em 9/3/2011 05:42, G=E1l Zsolt escreveu: > Here is an alternative based on the previous mentioned LC meters: > > http://www.hobbielektronika.hu/kapcsolasok/lcm3_alkatresz_mero_muszer_-_k= it_lehetoseg.html > > It measures series resistance of electrolitic capacitors and the > memory effect also. It is uses about 90kHz frequency for measureing > it. You can find the full documentation on that page. I offer google > translator for reading it. At 90kHz, this meter will also not work correctly for most electrolytic and polyester capacitors. The commercial LCR meters I know use two test frequencies, 120Hz and 1kHz. Isaac --=20 http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .