Em 11/2/2011 10:14, Tobias Gogolin escreveu: > The question I have is, what kind of switching power supply architecture = would be recommendable to match lets say a 50V motor (BLDC or Asynchronous)= which would be fed by a 300V Bank that cant really supply the max. power c= urrent of the motor? A buck step-down converter? What is the power of this motor? Keep in mind that a 20kW motor at 50V will need 400A. > How reasonable is it to hope that such an approach could actually be > beneficial and eliminate key problems of battery systems (matching, > balancing, cell failures). I would use a higher voltage motor to keep the current at lower levels and thus the losses low. Remember that the step-down converter also introduces some losses and such losses are proportional to the current. Best regards, Isaac __________________________________________________ Fale com seus amigos de gra=E7a com o novo Yahoo! Messenger=20 http://br.messenger.yahoo.com/=20 --=20 http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .