Matt Rhys-Roberts wrote: >> Apply the same voltage to all during production test and store >> calibration values in EEPROM. > > a) ADC and its attenuator (say 1% tol.) are calibrated once against a > precision external source This can be just as easily applied to multiple attenuators. > b) Multi HV unit can then self-calibrate each channel, as the > attenuator is switched between HV outputs. How is that self calibrating? You can't calibrate the system with a signal you are trying to measure. You need a reference somehow. If you're worrie= d about drift after initial calibration, then you have to occasionally switch in a calibrated input. However, I wouldn't call that "self calibrating". ******************************************************************** Embed Inc, Littleton Massachusetts, http://www.embedinc.com/products (978) 742-9014. Gold level PIC consultants since 2000. --=20 http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist .