At 08:21 AM 7/9/2010, you wrote: >Adam, > > > Any reason for 1K? Do you need the speed? You can probably use a > > bigger resistor like 10K or 22K and not have to sink so much current > > when you pull the line down. > >The SDA line connects tot he 24LC256 SEEPROM. The 1K pull up is >required. This used to work for me on other devices like 16C54, 16F870, etc. > >This is the first time I am using this on 16F676. You have set the relevant SCL/SDA port bits to 0 and are writing to the TRIS registers, not the port registers, to control SCL/SDA, right? >Best regards, Spehro Pefhany --"it's the network..." "The Journey is the reward" speff@interlog.com Info for manufacturers: http://www.trexon.com Embedded software/hardware/analog Info for designers: http://www.speff.com -- http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist