> I am curious..... WHY and WHY is shield cables NOT ALLOWED?! > = > John. > = One reason is if the circuit driving and receiving the data signal is not = floating with respect to the shield, then that circuit sees a lot higher = capacitive load from the shield which may restrict cable lengths and/or = communication speed. Another reason is potential ground loops if the shield is connected at both = ends (which it should be if it is to be of any use EMC wise). EX circuits, = for = example, should not have the shield connected at both ends when the cable i= s = connected between different zones. /Ruben =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D= =3D=3D=3D=3D=3D Ruben J=F6nsson AB Liros Electronic Box 9124, 200 39 Malm=F6, Sweden TEL INT +46 40142078 FAX INT +46 40947388 ruben@pp.sbbs.se =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D= =3D=3D=3D=3D=3D -- = http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist