Jinx wrote: > successively connected to the barrel. I'd have to experiment to find out > if it's ring then tip, and if ring disconnects when tip connects The connection sequence for an RS60E3 is: Shield Shield -> Ring Shield -> Ring, Shield -> Tip The switch has two positions -- half-travel and full-travel. At full travel, both contact pairs are closed. At half travel, only the focus pair is closed. I could swear I'd seen a copy of the internal schematic of the camera, at least as far as the shutter circuitry goes. Maybe try camerahacker? -- Phil. piclist@philpem.me.uk http://www.philpem.me.uk/ -- http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist