Xiaofan Chen wrote: >On 6/19/08, Ruben J=F6nsson wrote: > = > >>Yes, and 840VAC or 1080VDC is a relatively low voltage for these kind of = tests. >>Remember - this is to test insulation breakdown, not to test what voltage= s the >>components or circuits can withstand (unless they are part of the insulat= ion). >> = >> > >Actually the OP says 840VAC and 1080VDC for 2 seconds. This kind >of 2 seconds test is typically for production test only. I guess that 1080= VDC >is indeed a typo and should be 1200VDC as you mentioned. > >Normal UL or IEC Hi-Pot tests for insulation type tests are 1 minute. > >Xiaofan > > = > OK, you are more correct than I am. It's a typo. It was listed as = 1180VDC. = So, 1180,1200, whatever it takes. (Sorry, the movie Mr. Mom was on last = night!) Bill -- = http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist