Hello, is it normal that an oscilloscope probe put on a oscillating xtal doesn't stop it from oscillating (yes, it is normal, it has got 1M impedance and few pF after all). BUT if the xtal was stopped (the chip it's connected to was in power down mode) and I power it up WHILE the oscilloscope probe touches the xtal terminal, the oscillator will never start up. Now, is THIS normal? It seems a xtal has a very hard time starting up, but when started, it will work robustly. I didn't know this, I haven't read it anywhere in the past, and am wondering if it's the side effect of some other problem I haven't identified. Did you experience anything similar too? Greets, Mario -- http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist