Apptech wrote: > TERMINATION OF UNUSED OP AMPS: > > Connect unused opamps as a follower and then connect the > non-inverting input to a point that is within the common > mode range of the amplifier (preferably well within). > > - Where there is a choice > > - Select a connection point with minimum AC variation. > > - Select a point where the amplifier will have minimum > impact on the original functionality. One such point is probably the /output/ of the existing op-amp, rather than paralleling the input. In general, the input range is wider than the output range, and it's usually a low impedance point. > - Consider creating a simple 2 resistor divider where > the above conditions cannot be well met. > > - Not having any spare sections may be the best choice > if possible. Gerhard -- http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist