In SX Microcontrollers, SX/B Compiler and SX-Key Tool, bean wrote: Russ, The PWM command won't work, because a triac stays on until the AC goes to zero. So if the PWM output goes low just after the zero point, the triac will still stay on until the AC reaches zero again. Basically the PWM needs to monitor the AC zero crossing. Bean. ---------- End of Message ---------- You can view the post on-line at: http://forums.parallax.com/forums/default.aspx?f=7&p=1&m=240185#m240190 Need assistance? Send an email to the Forum Administrator at forumadmin@parallax.com The Parallax Forums are powered by dotNetBB Forums, copyright 2002-2008 (http://www.dotNetBB.com)