Dagmar, I use AD623 before very nice op. My suggestion is replace your resistor (ga= in) with 20k pot " for test only" and keep turning until it started working = properly. it looks like gain issue with INA126 you do not have enough gain. Andre Abelian -----Original Message----- From: piclist-bounces@mit.edu [mailto:piclist-bounces@mit.edu]On Behalf Of Dagmar C. Neto Sent: Thursday, November 08, 2007 10:02 AM To: piclist@mit.edu Subject: [EE] INA126 high offset problem Hi all, = I'm using the AD623 instrumentation amplifier to measure signal from a bri= dge = pressure transducer, and would like to replace it with the INA126 that have= a much smaller = quiescent current (175uA, against 500uA from AD623). However, it shows a hi= gh offset = voltage value at output (500mV), what leads to a very large voltage "dead b= and" - small = signals from sensor don't show at output until its amplification overcome t= his 0.5V value. I = don't have any of these problems with AD623. Anyone know what could be happen? In both amplifiers the REF input (pin 5)= is = grounded. The gain is set around 80 (1-1.2kohm gain resistor). Thank you all, = Best regards, Dagmar -- = Esta mensagem foi verificada pelo sistema de antiv=EDrus e acredita-se estar livre de perigo. -- = http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist