At 10:14 PM 6/19/2007, you wrote: >-----BEGIN PGP SIGNED MESSAGE----- >Hash: SHA1 > >I'm writing a feasibility report for a project that would involve >placing hundreds, or even thousands, of little nodes consisting of a >really low end PIC, 12f or even 10f, and an PWM'd LED, in trees >outdoors. The project is fairly cost sensitive, given the scale, so I >was thinking of some sort of software one-wire bus implemented on cheap >CAT3. After spending a few hours thinking everything else through, er, I >mean as a responsible first step, I thought I'd try to figure out the >characteristics of my transmission line: > >Nodes: 100 > >Distance needed: ~50ft/node to master, w/ star topology, 5000ft total > >CAT3 is 20pf/ft, 30ohms/1000ft > >20pf/ft * 5000ft = 100uF 1 pF is 10^-12 F. So you actually are looking at 100nF, not uF. Best regards, Spehro Pefhany --"it's the network..." "The Journey is the reward" speff@interlog.com Info for manufacturers: http://www.trexon.com Embedded software/hardware/analog Info for designers: http://www.speff.com -- http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist