Hi Forrest, For current, I=B4m using the Allegro Hall effect current sensors. I=B4m using the ACS series, for - 50 to + 50 A. The output is 0-5V with 0 A at 2.5V. = Best Regards, Rubens At 09:46 13/6/2007, you wrote: >I've been working on trying to design a circuit which will allow me to = >monitor state-of-charge and charge/discharge current for solar sites. = >I'd love to use the onboard ADC on a typical PIC to keep the cost down, = >but this isn't necessarily 100% a requirement. > >Array voltage is easy.. Just attach to ADC through some precision = >resistors and away you go. Current not so much, since I will be using = >a shunt to get the current information (unless there's an easier way to = >measure up to tens of amps DC). The basic configuration would be simply = >to measure the drop across one shunt, although it would be nice to be = >able to do more than one (I.E. one for the charge path and one for the = >discharge path, or perhaps one for solar in and one for wind in and one = >for load out). = > >If I require the shunt on the neutral side, I can then measure anything = >positive - but the negative swing is an issue. If the shunt is on the = >high side, then I have an issue with the high side rail. > >How do people typically measure + and - voltages which come off of the = >DCA shunt? > >-forrest >-- = >http://www.piclist.com PIC/SX FAQ & list archive >View/change your membership options at >http://mailman.mit.edu/mailman/listinfo/piclist -- = http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist