Peter P. yahoo.com> writes: > Turn-on with 3 x 10nF will cause a small current spike with 10nF across R1. > Adjust (lower the value) of the cap across R1 to avoid it. That would be, of course, 'increase the value'. F.ex. 10nF-100nF-10nF should work fine. But 3 x 10nF creates only a 250 uA shoot-through spike. Peter P. -- http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist