In SX Microcontrollers, SX/B Compiler and SX-Key Tool, Peter Van der Zee wrote: Hi Andrew; No, that is not the right way to fix this. Each character (byte) resyncs every time on detecting the start bit, so extra inter-character spaces should not be required. It IS a requirement of course that the sender transmit at least the number of stop bits that the receiver is expecting; one in this case. After that all should be OK if one samples the bits in a byte consistently at the same, and correct time. I'm sure we'll get James' issue dispatched with shortly. Cheers, Peter (pjv) ---------- End of Message ---------- You can view the post on-line at: http://forums.parallax.com/forums/default.aspx?f=7&p=2&m=109670#m111190 Need assistance? Send an email to the Forum Administrator at forumadmin@parallax.com The Parallax Forums are powered by dotNetBB Forums, copyright 2002-2006 (http://www.dotNetBB.com)