Everyone is making this more complicated than is needed. Simply put, a pause-charge method with minimum 10bit ADC for peak voltage detection is equal to commercial charge management solutions available today. Because batteries are chemical components in electrical designs, fixed point methods of battery management can never adapt to changes in battery charge/discharge efficiencies as the batteries age or are under non-typical loads. I'll post a Basic Stamp version shortly, and soon a C++ version. Steve Halla ----- Original Message ----- From: "Brian Aase" To: "Microcontroller discussion list - Public." Sent: Friday, October 28, 2005 3:24 PM Subject: Re: [EE] Charging NiMH > >> I progressed in -dV method and >> already achieved very satisfied results, after I found >> a better algorithm. Before, I was totally dislike -dV. > > If the better algorithm you found was public domain, would you > mind posting a pointer to it? > > Brian Aase > > -- > http://www.piclist.com PIC/SX FAQ & list archive > View/change your membership options at > http://mailman.mit.edu/mailman/listinfo/piclist > -- http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist