> The ADXL311 is in phase-out status according to AD. The > suggested replacement (ADXL320) has the information on the data > sheet (page 10). Maybe it's the same.. I think the package is too dissimilar to extract useful information from it. They chose a very interesting method for conveying the information, too. Phase-out isn't important; one-off and all that. Plus, the +/-5g range is a little more than I need. Since this is going to be used to measure tremors caused by pharmaceuticals, the actual acceleration range is pretty small- well within the range of the ADXL311. > The ADXL320 is a lot less bulky than the ADXL311 (< half the volume). ;-) Since this thing is being mounted dead-bug (if you can say that, for a chip with no "legs"), smaller is only better to a point. This will be dead-bugged to a substrate (piece of Delrin), which the wires will lead away from to connect to the amp/signal conditioning box, which then feeds into the rest of the data acquisition system. Mike H. -- http://www.piclist.com PIC/SX FAQ & list archive View/change your membership options at http://mailman.mit.edu/mailman/listinfo/piclist