From: p.cousens >Well no one has asked the really dumb question yet. There are no dumb questions for me! >You did say that the generator was drawing huge amounts of power. Yes, something in the range of 140-150 MVAR and som 40-50 MW. >You only show one phase being monitored by the sync. That=B4s right, phase B. >And I assume that you only have minimal excitation when you sync. We get the unit in what we call base excitation. The voltage goes to 17 = KV and the water force is limited to a minimum where the unit is self regulated to = the 60 Hz frecuency. > So I'll ask Is your phase rotation correct ? Yes my friend, it is. Thanks for the help, regards, *Carlos* --Guri, Venezuela-- -- http://www.piclist.com hint: PICList Posts must start with ONE topic: [PIC]:,[SX]:,[AVR]: ->uP ONLY! [EE]:,[OT]: ->Other [BUY]:,[AD]: ->Ads --- Incoming mail is certified Virus Free. Checked by AVG anti-virus system (http://www.grisoft.com). Version: 6.0.712 / Virus Database: 468 - Release Date: 27/06/04 --- Outgoing mail is certified Virus Free. Checked by AVG anti-virus system (http://www.grisoft.com). Version: 6.0.712 / Virus Database: 468 - Release Date: 27/06/04 -- http://www.piclist.com hint: PICList Posts must start with ONE topic: [PIC]:,[SX]:,[AVR]: ->uP ONLY! [EE]:,[OT]: ->Other [BUY]:,[AD]: ->Ads