> I suspect your real problem was not the 1200 baud drift, but the 38KHz > carrier drift going outside the IR receiver passband. Not likely, a 5% shift will kill asynchronous communication, but the common IR receivers that I know [ http://www.vishay.com/docs/82030/82030.pdf ] a 5% shift will reduce the sensitivity to 60%, hence the effective distance to 77%. Wouter van Ooijen -- ------------------------------------------- Van Ooijen Technische Informatica: www.voti.nl consultancy, development, PICmicro products -- http://www.piclist.com hint: PICList Posts must start with ONE topic: [PIC]:,[SX]:,[AVR]: ->uP ONLY! [EE]:,[OT]: ->Other [BUY]:,[AD]: ->Ads