The 1500uf cap looks like a direct short to the FWB for a good number of cycles. One other possible way is to step the voltage up from the bridge to the "isolated" mains by temporarily injecting a resistor in series with the mains and the FWB and then shorting it. Rick Chris Loiacono wrote: > I have put together a setup to PWM a 90V PM motor that uses an unregulated > 170V supply from the AC line in a low-side switching arrangement. The supply > consists of a 6A 400V FWB & a 1500uF cap. I wiped out a bridge when testing > this and reasoned that perhaps back EMF, or perhaps a program glitch may > have allowed a hard pulse to the MOSFET which would have made high inrush > current... -- http://www.piclist.com hint: PICList Posts must start with ONE topic: [PIC]:,[SX]:,[AVR]: ->uP ONLY! [EE]:,[OT]: ->Other [BUY]:,[AD]: ->Ads