Jochen Feldhaar schrieb: > > Hi Steve, > > everything is OK! > You have 50% duty cycle, and pp Voltage is double the RMS value (what > would be dissipated as equivalent DC in a resistor). > > I wonder why your results are so good in precision that I always get > suspicious that Mr. Murphy is lurking just around the corner.....hehehe Oh God, my English..... I wanted to say that results that tally so fine are a surefire indicator of a Murphy situation... Jochen > > Greets Jochen > > "Kosmerchock, Steve" schrieb: > > > > Friends, > > > > I am having a problem that I really need help with. > > I am trying to measure an AC squarewave at 800Hz with a > > dutycycle of 50%. I am using a Keithley 2000 multimeter > > set to read ACV. I need to measure the volts peak, the meter > > gives me the volts RMS. I figure I could do the formula but > > nothing matches. > > > > I am measuring 5.6Vpp and 2.8Vrms. This doesn't make any sense to > > me. When I measure the sinewave of an equivelant circuit everything > > works out mathematically. Could someone point me to a possible solution. > > I have a feeling I am missing / forgetting something trivial. > > > > Thanks in advance!! > > > > Best regards, > > Steve > > > > -- > > http://www.piclist.com hint: The PICList is archived three different > > ways. See http://www.piclist.com/#archives for details. > > -- > http://www.piclist.com hint: The PICList is archived three different > ways. See http://www.piclist.com/#archives for details. -- http://www.piclist.com hint: The PICList is archived three different ways. See http://www.piclist.com/#archives for details.