At 16:12 24/06/2002 -0400, Olin Lathrop wrote: > > That's what I do (I monitor ADIF in PIR1) but when I see ADIF=1 I still >wait > > an extra iteration. This is because in the mid-range reference manual I >have > > read that you must allow for at least 2 Tad extra between two consecutive > > acquisitions (actually after finishing the conversion but before starting > > the next acquisition). Isn't this correct? > >Yes, but you're going to wait at least 22uS anyway as I understand it. For the acquisition, yes. >You >do need to wait before starting the next conversion, but not before reading >the results or switching the channel after a conversion. OK, then I have read the manual wrongly -- I understood it was a delay before starting the new acquisition. Thanks for clarifying! Regarding the actual problem, do you think that noise could be the cause of the problem? If so, how would that translate to this $008 or $004 reading? Thanks! G. -- http://www.piclist.com#nomail Going offline? Don't AutoReply us! email listserv@mitvma.mit.edu with SET PICList DIGEST in the body