On Mon, 3 Jun 2002, Michael Imsic wrote: >Roman, > >The hot box consists of two 25 watt globes fitted to a large foam >container. The globes are wired to a dimmer switch which allows me to >control the temperature. I don't need prescise regulation, more over >temp protection. For example the heating turned off at about 40 deg. C >(104F) and back on again at 20 deg. C (68F). I would love to hear about >your incubator. Cannibalize a bimetal thermostat from a clothesiron or washing machine (has remote sensing bulb). This will fix your problem immediately. A good quality thermostat is overkill if you do not decide what part of the box you want to measure or if you do not have foorced circulation to keep everything at the same temperature. Peter -- http://www.piclist.com#nomail Going offline? Don't AutoReply us! email listserv@mitvma.mit.edu with SET PICList DIGEST in the body