Thanks, Chuck.- ----- Original Message ----- From: Chuck Mancuso To: Sent: Thursday, January 10, 2002 11:51 PM Subject: Re: [PIC]: Using LM35 ?? > At 02:13 1/10/2002 -0300, you wrote: > >Hi everyone, > > > > I=B4m trying to read negative temperature using LM35, and one 16F87= 7. > > It gives me 10mv/=BAC, so at -55=BA, I=B4ll have -550mv. > > But I want to have 0 Volt at -10=BAC, How do I change the zero posi= tion ?? > > > > It it for being able to read this temperature with the 16F877. > > > > Thanks in adavance.- > > > > Hi Gabriel, > > You'll need to scale it with an op-amp to get zero at -55. Just subtrac= t > 550mV from the LM35 voltage. > > We've used them at very cold temps. here and they work great. We use a look > up table instead of an op-amp to scale the temps. Much easier in our > situration. > > Good luck > > chuck > > > wmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwm > || Chuck Mancuso || i AEC Systems i || > || aecsys@mosquitonet.com || {|} Delta Junction {|} || > || || {{|}} Alaska {{|}} || > || || {((|))} USA {((|))} || > || www.mosquitonet.com/ || {{{{|}}}} {{{{|}}}}|| > || ~aecsys/ || ____|______________________|____|| > wmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwmwm > > -- > http://www.piclist.com#nomail Going offline? Don't AutoReply us! > email listserv@mitvma.mit.edu with SET PICList DIGEST in the body > > -- http://www.piclist.com hint: PICList Posts must start with ONE topic: [PIC]:,[SX]:,[AVR]: ->uP ONLY! [EE]:,[OT]: ->Other [BUY]:,[AD]: ->Ads