I have always understood 1/10C to be standard charge(at least for NiCd) for 10-16 Hrs., and trickle to be 1/50C which is usally safe to leave on all the time. It just compensates for self discharge. > > Hi Olin, we have always trickled charged our NiCds > > at 10% C (constant current source). > > Usually overnight, often for a couple of days > > if we forget. We get excellent use from all our NiCd > > powered test equipment, for many years. My personal > > opinion is that this is the best charging method, > > provided you don't need a quick charge. :o) > > > On the other hand, I've seen other manufacturers explicitly state that > trickle charging at .1C indefinitely causes no ill effects. Perhaps there > are slightly different chemistries. > -- http://www.piclist.com hint: PICList Posts must start with ONE topic: [PIC]:,[SX]:,[AVR]: ->uP ONLY! [EE]:,[OT]: ->Other [BUY]:,[AD]: ->Ads