Hi James, Check out http://www.cix.co.uk/~pplunkett/x10.htm. This may be of some use. Also http://www.national.com/an/AN/AN-146.pdf this is an old appnote for sending FM through the AC line but it specifies line signal xformers. I used these with appropriate caps to tune to the x10 signal frequency. The part numbers have changed since the appnote. The parts I ordered many years ago were TOKO RAN 10A6729 for the Tx xformer, and RAN 10A6845 for the Rx xformer, they may gave changed since then? There's also an x10 module TW523 that provides logic level x10 RX, TX and zero crossing and a PIC based Weeder Technologies Home Automation Controller that allows serial/ASCII control of the TW523. Hope this helps, Heinz At 11:51 AM -0700 5/29/01, James Newton. Admin 3 wrote: >Has anyone done the PIC to X10 thing? > >....... > >I am currently working on a x-10 type project and I'm finding difficulty in >transmitting a signal from a pic 16f84 over the mains. Any help on this >subject, including schematics and code would be very appreciated. ' > -- http://www.piclist.com#nomail Going offline? Don't AutoReply us! email listserv@mitvma.mit.edu with SET PICList DIGEST in the body