Peter Tiang wrote: > > > I monitor chging V & T - The batteries tracked the voltage > > droop per the data sheet closely at first, but the effect > > disappeared early on. > > > > I was never able to observe the described temp behaviour. > > That's weird, did you observe the temp close > to the cell or outside the battery pack ? Thermocouple probe of a Wavetek 28XT taped to a cell. > > What is very noticeable is the rate at which V_chg increases > > with increasing ambient T. > > If I remembered correctly, you should be > monitoring the pack voltage when the current > source is removed. > > This will take care of the voltage drop due to > charging current which will vary with cell > impedance (which is a function of T). > > Incidentally, this method of "pulsed" constant > current charge is better at preventing dendrites > formation in the battery cells. Checked the data sheet, no mention of measurement protocol. I bet you're right. I'll give it a try, thanks. regards, Jack -- http://www.piclist.com hint: The list server can filter out subtopics (like ads or off topics) for you. See http://www.piclist.com/#topics