Olin wrote: >> Yeah, who/what can be trusted at all anymore? I put my sine >> generator to the cap marked 220 thru a 10K [5%] resistor, and >> adjusted freq until the voltage across the cap dropped to 50% >> on the scope. Using Xc = 1/(2*pi*F*C) > >That's the magnitude of the impedance, but is not valid the way you used it >due to being 90 degrees out of phase with the resistor. > Thank you - as was also brought to my attention by RichO. [I am now limping off into the sunset on my single living brain cell]. -- http://www.piclist.com hint: To leave the PICList mailto:piclist-unsubscribe-request@mitvma.mit.edu