> > Note that when two CCP modules are used with one in capture mode and the > > other in compare mode, that the compare has to be configured as the > special > > event trigger, which clears timer 1. > > Oh no! Is this really the case? ... According to the manual for the 16F87x it is. See "Table 8-2: Interaction of two CCP Modules" on page 57. This may be different on other PICs - I haven't looked. I also haven't personally played with this, but there is little reason to doubt such a direct assertion in the manual. ***************************************************************** Olin Lathrop, embedded systems consultant in Devens Massachusetts (978) 772-3129, olin@cognivis.com, http://www.cognivis.com -- http://www.piclist.com#nomail Going offline? Don't AutoReply us! use mailto:listserv@mitvma.mit.edu?body=SET%20PICList%20DIGEST