Adam: How work the laser measurement of liquid (water) level ? Do you know something that sell this sensores ready to use ? With respect to wet sand properties, i don't have more information that you.. sorry I am in the beggining of my project and recolecting information, I am not a expert on sand and concret ;-) TIA. Hugo ----- Original Message ----- From: M. Adam Davis Sent: Tuesday, May 30, 2000 10:22 AM Subject: Re: [EE][PIC] How to measure level of liquids and sense relativehumidity? > You are putting this into a concrete plant? You should really use some sort of > industrial solution. A number of companies make non contact and contact > distance sensors specifically for liquid level measurement. The one I am > thinking of now for your application is a non contact laser liquid level sensor, > which you simply point down on the liquid. Many of these can be used in > corrosive environments (glass, stainless steel, etc) as well. > > As far as the water content of sand, the only thing I can think of would be to > take a certian volume of the sand, and weigh it. The same volume will be > heavier the more damp it is. I don't think the usual method of electrodes > spaced so far apart will be very accurate (nevermind having to replace them > every month, and recalibrate them daily due to wear) Most dampness/humidity > sensors require contact with the substance you are measuring. Perhaps you can > tell us more about the properties of wet sand. Does it reflect a lightsource > differently depending on its dampness? > > -Adam > > Hugo Jorge M|ller wrote: > > > > Hello > > > > I am beginning to work in the final project of my career of Electronic > > Engineering and at the moment, we have decided to make the following work > > (with a friend): To automate a plant of Concrete. > > > > The idea is to use a PC for the general control of the plant and to arm a > > network (Possibly RS485) with terminals that will be slaves working with > > PICs, to complete different tasks, as the following ones: > > > > 1) To control the pneumatic servos and read proximity sensores and other. > > > > 2) To Sense the weight of the materials with cells of loads, indicate the > > value measured in a 7 segments display and to send the measures througt the > > network when they are requested or periodically. This partly would be > > resolved, but I accept ideas and suggestions in this respect. > > > > 3) To Sense the level of water in the main dosificador tank. The tank should > > be filled until certain level and then it is pumped to the truck concrete > > mixer. I have think in sense the height of the column of liquid with a > > sensor of pressure Motorola of the series MPX, I also thought of the > > ultrasonic solution but I don't have idea that resolution i can achieve. > > The tank in question has 1100 Liters and a height of about 2 meters. aprox., > > it is cylindrical. I need a precision of about 5 liters. (or better). > > Ideas? Comments? Other viable methods? > > On the other hand I should dose some aditives, special liquids that > > unfortunately they are corrosive and at the moment it is filled a small tank > > of about 26 liters by means of a key, for graveness, then they closes this > > key (superior) and two keys open up, one in the inferior part that allows > > the exit of the preservative toward the MIXER and the other one in the > > superior part that injects compressed air at 10 Kg/cm^2 to impel to the > > preservative and to pump it without having contact with the same one. > > The problem is to measure the level or the quantity of this aditive without > > touch it and to be able to pump it too to the mixer. > > I thought of measuring it with sensor MPX, but the problem is when opening > > the key of compressed air, the sensor doesn't support 10 Kg/cm^2 (although > > it could measure in differential form, but I suppose that the transitory one > > provoked, it would destroy to the silicon sensor). > > Here it is where I request them help that mensuration methods advise me? > > > > Somebody had worked with sensor MPX with PICs ? What kind of interface/ ADC > > use ? > > > > 4) Another topic not less difficult of solving it is to be able to measure > > the relative humidity that there is in the sand and in the concrete once > > blended. Here the only method that I am happened (electronic) it is between > > two by means of the mensuration of conductivity electrodes of a material > > that is not oxidized, located inside the material to measure, at a certain > > distance. That other methods or variantes suggests me? > > > > As for the net RS485, has somebody used them with PICs? That protocols > > suggest? Some link with information? > > > > Good, I won't extend more in the detail, I wait their collaboration with > > ideas... > > > > Sorry if there are errors in the text, but my language is Spanish :-) > > > > Thank you from already. > > > > Hugo J. M|ller > > H.J.M. Hardware & Software Diseqos Electrsnicos > > San Nicolas 683 > > Tel-Fax : 54-(0)-343-424-5953 > > (3100) Parana (Entre Rmos) Argentina > > Email : hmuller [ANTISPAM-QUITAR-ESTO] @arnet.com.ar > > Web Site: http://www.pagina.de/hjm > > UIN (ICQ) : 38.605.074 >