On Wed, 10 Mar 1999 09:34:45 +1100, Tony Nixon wrote: > >You may need to isolate the SCR from the PIC. > I just finished the first prototype of a unit that controls a Cheston heater. It's phase controled via 2 inverse parallel SCR's which at peak run 350 amps at 480 VAC. To achive the proper isolation beetween the SCR's and the CPU I had to use a gate trigger transformer. The CPU sits on the primary side and the SCR is on the secondary side connected to the anode and the gate. To fire the scr you pulse the xformer. This sends several large spikes into the gate and turns on the SCR. Be warned all gate xformers are not created equal and you need to do a little research to get right one for your SCR. (Or at least in my case they were) -- Richard A. Smith Bitworks, Inc. rsmith@bitworks.com 501.521.3908 Sr. Design Engineer http://www.bitworks.com